 1560-01-061-7216 | PANEL,LOWER,HEAT EXCHANGER | 06/28/1978 |
|
 1560-01-061-7216 | PANEL,LOWER,HEAT EXCHANGER | | 0 |
|
 | | METAL DYNAMICS INTERNATIONAL CORPORATION | 0 | For additional information Register for Free Trial
|
For additional information Register for Free Trial
|
 4W12553-149A | CPI AEROSTRUCTURES INC | 9U679 | 4W12553-149A | LOCKHEED MARTIN CORP | 98897 | 4W12553-149A | HONEYCOMB COMPANY OF AMERICA, INC. | 99115 | For additional information Register for Free Trial
|
 END ITEM IDENTIFICATION | ACFT MODEL NO. C-5A | GENERAL CHARACTERISTICS ITEM DESCRIPTION | ALUMINUM ALLOY WITH HONEYCOMB,60.000 IN. LG,37.000 IN. W,1.375 IN. THK | For additional information Register for Free Trial
|
 ACQUISITION METHOD CODE. | 'All Departments | 1 | SUITABLE FOR COMPETITIVE ACQUISITION. |
| ACQUISITION METHOD SUFFIX CODE. | 'All Departments | C | THIS PART REQUIRES ENGINEERING SOURCE APPROVAL BY THE DESIGN CONTROL ACTIVITY IN ORDER TO MAINTAIN THE QUALITY OF THE PART. AN ALTERNATE SOURCE MUST QUALIFY IN ACCORDANCE WITH THE DESIGN CONTROL ACTIVITY’S PROCEDURES, AS APPROVED BY THE COGNIZANT GOVERNMENT ENGINEERING ACTIVITY. VALID AMCS: 1, 2, 3, 4 AND 5. |
| MAJOR ORGANIZATIONAL ENTITY. | Air Force | DF | Air Force | Navy | DN | Navy | Defense Logistics Agency. | DS | Defense Logistics Agency. |
| PRICE | All Departments | Price | 8108.61 |
| PRECIOUS METALS INDICATOR CODES. | All Departments | A | Item does not contain Precious Metal. |
| CRITICALITY CODE. | All Departments | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| AUTOMATIC DATA PROCESSING EQUIPMENT. | | ELECTROSTATIC DISCHARGE CODE. | | HAZARDOUS MATERIALS INDICATOR CODE. | All Departments | P | Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. |
| DEMILITARIZATION CODE. | All Departments | Q | Commerce Control List Items (CCLI) – Mutilation to the point of scrap required outside the United States. In the United States, mutilation requirement determined by the DEMIL Integrity Code. DoD Trade Security Controls (TSC) required in the United States. (Note 8). |
| For additional information Register for Free Trial |
|  | | PANEL, LOWER HEAT EXCHANGER LOCKHEED MARTIN CORP, EXCEPTIONS OWENS-CORNING E-18 THREAD ACCEPTABLE SUBS ARE: #18 TEFLON COATED THREAD, LEWCO SPECIALITY PROD. INC, SYNTHETIC THREAD CO., & WF LAKE CORP--P/N 753-18. USE BAC5555 ILO STP58-209 FOR PRODUCTION ITEMS. ECO 2001C0001 APPLIES. SOURCES: GOVERNMENT FIRST ARTICLE TESTING REQUIRED: SPECIFICS OF FIRST ARTICLE TESTING: A) FORM, FIT + FUNCTION, B) X-RAYS FOR CORE DEFECTS OR WATER ENTRAPMENT AND C) ULTRASONIC FOR DISBONDING. ORIGIN INSPECTION REQUIRED. MARK IAW MIL-STD-130N, DATED 17 DEC 2007. CONFIGURATION CONTROL APPLIES SEE CLAUSE 52.246-9G36 (SECTION I). TECH DATA PACKAGE AVAILABILITY: DSCR MAY NOT HAVE AN APPROVED BIDSET FOR THIS NSN. SAMPLING: 1. SAMPLING FOR INSPECTION AND TESTING SHALL BE IAW ANSI/ASQ Z1.4-2008, DATED JAN 1, 2008. ANY ALTERNATE PLAN MUST BE APPROVED BY THE PCO. A SAMPLING PLAN THAT ACCEPTS ON ZERO DEFECTS IS REQUIRED 2. ANY DEFECTIVE ITEM DISCOVERED DURING INSPECTION MAY BE CAUSE FOR REJECTION OF THE ENTIRE CONTRACT QUANTITY. Government First Article Preproduction approval required. Testing will be in accordance with applicable drawings, specifications and/or Engineering instructions. The first article offered shall be manufactured at the facilities in which production quantities are procured and produced under this contract. When submitting the first article(s) for government testing, a copy of the contract and all applicable drawings, specifications, engineering instructions, certifications, and inspection sheets shall be provided. Upon receipt and evaluation of the test report from the responsible government testing location, the contracting officer will provide final notification to the manufacturer. Any questions or concerns regarding the first article test requirements must be submitted through the contracting officer. Additional Wide Area Workflow (WAWF) instructions for government first article test CLIN: The contractor shall code the receiving report for government first article test CLIN in WAWF as Follows: Inspection at origin (Source)- Enter the DCMA office DODAAC listed on page 1 of the contract. Acceptance by other-Enter the issue by office DODAAC listed on page 1 of the contract. Ship to code-Enter the DODAAC of the test facility listed for the government first article test CLIN in the contract (See FAR Clause 52.209-4). FIRST ARTICLE TEST MARKING INSTRUCTIONS: FAT sample(s) packaging shall be clearly marked "FIRST ARTICLE TEST EXHIBIT(S) DO NOT POST TO STOCK!!!" in largest font possible with contrasting color to the packaging. Marking shall be located adjacent to the Package Shipping Label side and on at least one additional side of the package. . | Cage# 98897 and PartNumber# 4W12553-149A Cage# 99115 and PartNumber# 4W12553-149A Cage# 9U679 and PartNumber# 4W12553-149A |
|
|
|
|
|
|
|
|
|