Search Criteria

NSN/NIIN No.:
Part No. :
(13-16 digit NSN/9 digit NIIN)
1650-01-058-61571620-01-058-6155
NSNDescriptionAssign Date
1620-01-058-6156LOCK,INNER STEERING COLLAR03/29/1978
NSNDescriptionDetailOpen Solicitations
1620-01-058-6156LOCK,INNER STEERING COLLAR0
Part NumberDescriptionCompanyQuantity
2006646-1LOCK,INNER STEER GMS INTERNATIONAL CORPORATION0
2006646-1LOCK, INNER-STEERING COLLAR,NLG,SHK STRU ONTIC ENGINEERING & MANUFACTURING, INC1
For additional information Register for Free Trial
Part NumberCompanyCAGE
2006646-1GOODRICH CORPORATION13002
2006646-1GOODRICH CORP DBA GOODRICH CORP17576
2006646-1GOODRICH CORPORATION6K4C8
For additional information Register for Free Trial
NameValue
END ITEM IDENTIFICATIONF-16 ACFT
GENERAL CHARACTERISTICS ITEM DESCRIPTIONSTEEL 4130 MIL-S-18729,CADMIUM PLATE TYPE 2 CLASS 3 QQ-P-416,T SHAPED 1.190 IN. LG,0.780 IN. H,0.125 IN. THK
For additional information Register for Free Trial
CodeDefinition
ACQUISITION METHOD CODE.
'All Departments1SUITABLE FOR COMPETITIVE ACQUISITION.
ACQUISITION METHOD SUFFIX CODE.
'All DepartmentsGTHE GOVERNMENT HAS UNLIMITED RIGHTS TO THE TECHNICAL DATA AND THE DATA PACKAGE IS COMPLETE. VALID AMCS: 1 AND 2.
MAJOR ORGANIZATIONAL ENTITY.
Air ForceDFAir Force
NavyDNNavy
Defense Logistics Agency.DSDefense Logistics Agency.
PRICE
All DepartmentsPrice38.19
PRECIOUS METALS INDICATOR CODES.
All DepartmentsAItem does not contain Precious Metal.
CRITICALITY CODE.
All DepartmentsXThe item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
AUTOMATIC DATA PROCESSING EQUIPMENT.
All Departments
ELECTROSTATIC DISCHARGE CODE.
All Departments
HAZARDOUS MATERIALS INDICATOR CODE.
All DepartmentsNIndicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
DEMILITARIZATION CODE.
All DepartmentsQCommerce Control List Items (CCLI) – Mutilation to the point of scrap required outside the United States. In the United States, mutilation requirement determined by the DEMIL Integrity Code. DoD Trade Security Controls (TSC) required in the United States. (Note 8).
For additional information Register for Free Trial
LOCK,INNER STEERING COLLAR,N/L/G STRUT P/N 2006646-1 DWG EXCEPTIONS: 1.MATERIAL:4130 STEEL PER SAE AMS 6350 IN LIEU OF MIL-S-18729. 2.IDENTIFICATION AND MARKING PER MIL-STD-130 IN LIEU OF TM1040. 3.SURFACE TEXTURE PER ASME B46.1 IN LIEU OF ASA B46.1. 4.DIMENSIONING AND TOLERANCING PER ASME Y14.5 IN LIEU OF ANSI Y14.5-1973. 5.CAD PLATE PER SAE AMS-QQ-P-416 IN LIEU OF MM4951, MM5542 AND QQ-P-416. 6.CORROSION PROTECTION PER MIL-C-16173, GRADE 1 OR MIL-C-11796, CLASS 1 OR 2 IN LIEU OF MM5752. 7.PERFORM MAGNETIC PARTICLE INSPECTION PER ASTM E 1444 IN LIEU OF MIL-I-6866. USE FLUORSCENT TYPE, FULL WAVE DIRECT CURRENT (FWDC), AND WET CONTINUOUS METHOD WITH THE FOLLOWING ACCEPTANCE/REJECTION CRITERIA: NO RELEVANT DEFECTS ALLOWED. THE INTENT OF NO RELEVANT DEFECTS ALLOWED IS THAT THE INSPECTION IS CONDUCTED AT THE REQUIRED SENSITIVITY LEVEL AND THERE SHALL BE NO RELEVANT INDICATIONS ALLOWED. THE INSPECTOR PERFORMING THE INSPECTIONS SHALL BE CERTIFIED TO LEVEL II WITH THE INSPECTION PROCEDURE DEVELOPED BY A LEVEL III AS SPECIFIED IN THE AIA/NAS-410. 8.APPLY ONE COAT EPOXY WATERBORNE PRIMER PER MIL-PRF-85582, TYPE I, CLASS C2. ALTERNATED ONE COAT OF EPOXY POLYAMIDE PRIMER PER MIL-PRF-23377, TYPE I, CLASS C2. 9.APPLY TWO TOP COATS POLURETHANE PER MIL-PRF-85285, TYPE I, COLOR NUMBER 17925 (WHITE) PER FED-STD-595, IN LIEU OF MIL-C-83286. 10. 515 CBSS/GBEA SYSTEM RETAINS ALL RIGHTS TO REVIEW AND ACCEPT MATERIAL REVIEW BOARD (MRB) DISPOSITIONS PRIOR TO SHIPMENT OF DISCREPANT ITEM. ALL DEVIATIONS, MINOR AND MAJOR, FROM THE ENGINEERING DRAWING PACKAGE SHALL BE SUBMITTED FOR MRB DISPOSITION. 11.PRIOR TO CONTRACT AWARD, THE CONTRACTOR SHALL CERTIFY TO THE GOVERNMENT IN WRITING FULL COMPLIANCE WITH MANUALS, SPECIFICATIONS, AND STANDARDS CALLED OUT AND REQUIRED FOR THE MANUFACTURE OF THIS CONTRACTED LANDING GEAR COMPONENT/ASSEMBLY. CONTRACTOR IS RESPONSIBLE TO COMPLETELY SEARCH THESE MANUALS, SPECIFICATIONS, AND STANDARDS AND FULLY UNDERSTAND THE REQUIREMENTS NECESSARY TO MANUFACTURE LANDING GEAR COMPONENTS. ANY QUESTIONS CAN BE FORWARDED TO THE OFFICE OF 515 CBSS/GBEA. Government First Article Preproduction approval required. Testing will be in accordance with applicable drawings, specifications and/or Engineering instructions. The first article offered shall be manufactured at the facilities in which production quantities are procured and produced under this contract. When submitting the first article(s) for government testing, a copy of the contract and all applicable drawings, specifications, engineering instructions, certifications, and inspection sheets shall be provided. Upon receipt and evaluation of the test report from the responsible government testing location, the contracting officer will provide final notification to the manufacturer. Any questions or concerns regarding the first article test requirements must be submitted through the contracting officer. Additional Wide Area Workflow (WAWF) instructions for government first article test CLIN: The contractor shall code the receiving report for government first article test CLIN in WAWF as Follows: Inspection at origin (Source)- Enter the DCMA office DODAAC listed on page 1 of the contract. Acceptance by other-Enter the issue by office DODAAC listed on page 1 of the contract. Ship to code-Enter the DODAAC of the test facility listed for the government first article test CLIN in the contract (See FAR Clause 52.209-4). FIRST ARTICLE TEST MARKING INSTRUCTIONS: FAT sample(s) packaging shall be clearly marked "FIRST ARTICLE TEST EXHIBIT(S) DO NOT POST TO STOCK!!!" in largest font possible with contrasting color to the packaging. Marking shall be located adjacent to the Package Shipping Label side and on at least one additional side of the package. FAT APPLIES:GOVERNMENT ADDITIONAL FAT INFORMATION: ATTN: CONTRACTOR AND SERVICE ACTIVITY TEST MONITIOR........................................ DISAPPROVED FIRST ARTICLE(S) SHALL BE RETURNED TO THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. APPROVED AND CONDITIONALLY APPROVED FIRST ARTICLE(S) SHALL BE RETAINED AT THE SERVICE TEST ACTIVITY UNTIL DISPOSITION INSTRUCTIONS ARE RECEIVED FROM THE PCO. IF DISPOSITION INSTRUCTIONS ARE NOT RECEIVED WITHIN 30 DAYS AFTER PROVIDING THE FIRST ARTICLE TEST REPORT TO DSCR, REQUEST THAT THE DSCR QA SPECIALIST BE NOTIFIED....................... IDENTIFY TO: MARK IAW MIL-STD-130N, DATED 17 DEC 2007. CONFIGURATION CONTROL APPLIES SEE CLAUSE 52.246-9G36 (SECTION I). SAMPLING: 1. SAMPLING FOR INSPECTION AND TESTING SHALL BE IAW ANSI/ASQ Z1.4-2008, DATED JAN 1, 2008. ANY ALTERNATE PLAN MUST BE APPROVED BY THE PCO. A SAMPLING PLAN THAT ACCEPTS ON ZERO DEFECTS IS REQUIRED 2. ANY DEFECTIVE ITEM DISCOVERED DURING INSPECTION MAY BE CAUSE FOR REJECTION OF THE ENTIRE CONTRACT QUANTITY. EXPORT CONTROL: THIS ITEM HAS TECHNICAL DATA SOME OR ALL OF WHICH IS SUBJECT TO EXPORT-CONTROL REGULATIONS. DISTRIBUTION OF THE TECHNICAL DATA AND ELIGIBILITY FOR AWARD ARE LIMITED TO THOSE SUPPLIERS QUALIFIED THROUGH JCP CERTIFICATION, OR TO THOSE LICENSED BY EITHER THE DEPARTMENTS OF STATE OR COMMERCE; OR TO FOREIGN SUPPLIERS PURSUANT TO INTERNATIONAL AGREEMENTS. TO APPLY FOR JCP CERTIFICATION, COMPLETE DD FORM 2345, "MILITARY CRITICAL TECHNICAL DATA AGREEMENT," FORM IS AVAILABLE AT THE WORLD WIDE WEB ADDRESS HTTP://WWW.DLIS.DLA.MIL/JCP OR BY WRITING TO: DLA LOGISTICS INFORMATION SERVICE FEDERAL CENTER 74 WASHINGTON AVE., NORTH BATILE CREEK, MI 49017-3084 TO MANUFACTURE THIS ITEM, NON-JCP CERTIFIED SUPPLIERS MUST SUBMIT A CURRENT MANUFACTURING LICENSE AGREEMENT, TECHNICAL ASSISTANCE AGREEMENT, DISTRIBUTION AGREEMENT OR OFF-SHORE PROCUREMENT AGREEMENT APPROVED BY THE DIRECTORATE OF DEFENSE TRADE CONTROLS WITH THE OFFER, UNLESS AN EXEMPTION UNDER THE PROVISIONS OF ITAR SECTION, 125.4 "EXEMPTIONS OF GENERAL APPLICABILITY," AND/OR EAR PART 740 ARE APPLICABLE. NON-JCP CERTIFIED SUPPLIERS SEEKING EXPORT CONTROLLED TECHNICAL DATA ARE REQUIRED TO PROVIDE THE CONTRACTING OFFICER WITH AN APPLICABLE AGREEMENT OR IDENTIFY WHICH ITAR/EAR EXEMPTION APPLIES TO RECEIVE A COPY OF THE EXPORT CONTROLLED TECHNICAL DATA. NOTE: JCP CERTIFIED CONTRACTORS WHO RECEIVE TECHNICAL DATA PURSUANT TO THEIR DD FORM 2345 CERTIFICATION MAY NOT FURTHER DISSEMINATE SUCH DATA UNLESS FURTHER DISSEMINATION OF THE TECHNICAL DATA IS EXPRESSLY PERMITTED BY DODD 5230.25." CRITICAL APPLICATION ITEM
Cage# 13002 and PartNumber# 2006646-1
Doc. NumberDoc. TypeDoc. Def.Doc. CodeDoc. DateAmdt. DateCage
2006646DWGBASICDD11/05/198209/24/2006 17576
010586156-06038DWGBASICRE02/07/200609/22/2006 13873