CONNECTION TYPE | THREADED INTERNAL TUBE 1ST END |
MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
MEASURING METHOD AND LENGTH | 14.125 INCHES NOMINAL OVERALL |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
TEMP RATING | -40.0 DEG FAHRENHEIT AND |
| 300.0 DEG FAHRENHEIT SINGLE RESPONSE |
MAXIMUM OPERATING PRESSURE | 750.0 POUNDS PER SQUARE INCH |
HYDROSTATIC TEST PRESSURE | 1500.0 POUNDS PER SQUARE INCH |
BURST TEST PRESSURE | 3000.0 POUNDS PER SQUARE INCH |
OUTER COVERING ENVIRONMENTAL PROTECTION | FUEL RESISTANT AND |
| OIL RESISTANT AND |
| WATER RESISTANT |
LAYER COMPOSITION AND LOCATION | 2ND LAYER BRAIDED STEEL WIRE AND |
| OUTER LAYER MOLDED RUBBER AND |
| 1ST LAYER BRAIDED COTTON CORD |
MINIMUM INSIDE BENDING RADIUS | 6.500 INCHES |
INSIDE DIAMETER | 0.617 INCHES MINIMUM AND |
| 0.648 INCHES MAXIMUM |
OUTSIDE DIAMETER | 0.883 INCHES MINIMUM AND |
| 0.979 INCHES MAXIMUM |
INSIDE SURFACE CONDITION | SMOOTH |
CONNECTION STYLE | SWIVEL NUT FLARE 1ST END |
SEAT ANGLE | 37.0 DEGREES 1ST END |
END CONNECTION DESIGN | STRAIGHT 1ST END |
THREAD SERIES DESIGNATOR | UNF 1ST END |
NOMINAL THREAD SIZE | 1.062 INCHES 1ST END |
THREAD QUANTITY PER INCH | 12 1ST END |
THREAD CLASS | 3B 1ST END |
THREAD DIRECTION | RIGHT-HAND 1ST END |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 19207 |
DESIGN CONTROL REFERENCE | 10932437 |