| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END CONNECTION DESIGN | STRAIGHT SECOND END |
| BURST TEST PRESSURE | 400.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | CAM OR LEVER (EXTERNAL) SECOND END |
| CONNECTION STYLE | CAM OR LEVER (INTERNAL) FIRST END |
| CONNECTION TYPE | EXTERNAL QUICK DISCONNECT SECOND END |
| CONNECTION TYPE | INTERNAL QUICK DISCONNECT FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| HYDROSTATIC TEST PRESSURE | 175.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 2.000 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER HELIX WIRE COIL AND 2ND LAYER BRAIDED COTTON CORD AND 3RD LAYER HELIX WIRE COIL AND OUTER LAYER MOLDED RUBBER, CHLOROPRENE |
| OUTER COVERING ENVIRONMENTAL PROTECTION | MILDEW RESISTANT |
| OUTSIDE DIAMETER | 2.718 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 96.000 INCHES NOMINAL OVERALL |
| MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| QUICK DISCONNECT NOMINAL SIZE | 2.000 INCHES FIRST END |
| QUICK DISCONNECT NOMINAL SIZE | 2.000 INCHES SECOND END |
| SPECIFICATION/STANDARD DATA | 81349-MIL-H-27516 GOVERNMENT SPECIFICATION |
| TEMP RATING | -42.0 FAHRENHEIT AND 75.0 FAHRENHEIT SINGLE RESPONSE |