| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END CONNECTION DESIGN | STRAIGHT SECOND END |
| BURST TEST PRESSURE | 1700.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | FLARE SECOND END |
| CONNECTION STYLE | PLAIN FIRST END |
| CONNECTION TYPE | THREADED INTERNAL PIPE SECOND END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| HYDROSTATIC TEST PRESSURE | 850.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.188 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | OUTER LAYER MOLDED RUBBER, SYNTHETIC AND 1ST LAYER BRAIDED COTTON CORD |
| OUTER COVERING ENVIRONMENTAL PROTECTION | FUEL RESISTANT AND MILDEW RESISTANT AND OIL RESISTANT AND OZONE RESISTANT AND COLD RESISTANT |
| OUTSIDE DIAMETER | 0.437 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 216.000 INCHES NOMINAL EXCLUDING END FITTINGS |
| MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| NOMINAL THREAD SIZE | 0.438 INCHES FIRST END |
| NOMINAL THREAD SIZE | 0.125 INCHES SECOND END |
| OPERATING PRESSURE | 425.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| SEAT ANGLE | 45.0 DEGREES FIRST END |
| TEMP RATING | -65.0 FAHRENHEIT AND 250.0 FAHRENHEIT SINGLE RESPONSE |
| THREAD CLASS | 2A FIRST END |
| THREAD DIRECTION | RIGHT-HAND FIRST END |
| THREAD DIRECTION | RIGHT-HAND SECOND END |
| THREAD QUANTITY PER INCH | 20 FIRST END |
| THREAD SERIES DESIGNATOR | NPTF SECOND END |
| THREAD SERIES DESIGNATOR | UNF FIRST END |