| END CONNECTION DESIGN | STRAIGHT FIRST END |
| BURST TEST PRESSURE | 20000.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | INVERTED FLARE FIRST END |
| CONNECTION TYPE | THREADED EXTERNAL PIPE FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| HYDROSTATIC TEST PRESSURE | 10000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.242 INCHES MINIMUM AND 0.273 INCHES MAXIMUM |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | OUTER LAYER BRAIDED STEEL WIRE |
| OUTER COVERING ENVIRONMENTAL PROTECTION | HYDRAULIC SOLUTION RESISTANT AND MILDEW RESISTANT AND OZONE RESISTANT AND COLD RESISTANT |
| OUTSIDE DIAMETER | 0.658 INCHES MINIMUM AND 0.718 INCHES MAXIMUM |
| MEASURING METHOD AND LENGTH | 17.900 INCHES MINIMUM OVERALL AND 18.100 INCHES MAXIMUM OVERALL |
| MEDIA FOR WHICH DESIGNED | HYDROGEN SINGLE RESPONSE |
| MINIMUM INSIDE BENDING RADIUS | 4.000 INCHES |
| NOMINAL THREAD SIZE | 0.250 INCHES FIRST END |
| OPERATING PRESSURE | 4500.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| SEAT ANGLE | 30.0 DEGREES FIRST END |
| TEMP RATING | -65.0 FAHRENHEIT AND 250.0 FAHRENHEIT SINGLE RESPONSE |
| THREAD DIRECTION | RIGHT-HAND FIRST END |
| THREAD QUANTITY PER INCH | 18 FIRST END |
| THREAD SERIES DESIGNATOR | NPTF FIRST END |