| END CONNECTION DESIGN | ELBOW FIRST END |
| END FLANGE CONSTRUCTION | SOLID FIRST END |
| ANGLE BETWEEN RIGID ELBOW FITTINGS IN DEG | 137.0 |
| BURST TEST PRESSURE | 3000.0 POUNDS PER SQUARE INCH |
| CONNECTION TYPE | RECESSED FLANGE FIRST END |
| CONNECTION STYLE | RECESSED FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE STYLE | RECTANGULAR (INCLUDES SQUARE) FIRST END |
| FLOW ANGLE | 45.0 DEGREES FIRST END |
| HYDROSTATIC TEST PRESSURE | 2000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 1.101 INCHES MINIMUM AND 1.156 INCHES MAXIMUM |
| INSIDE SURFACE CONDITION | SMOOTH |
| ITEM STRUCTURAL COMPOSITION | BRAIDED CORROSION RESISTANT STEEL WIRE FIRST LAYER |
| ITEM STRUCTURAL COMPOSITION | BRAIDED CORROSION RESISTANT STEEL WIRE OUTER LAYER |
| OPERATING PRESSURE | 1000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| OUTSIDE DIAMETER | 1.359 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 30.000 INCHES NOMINAL WORKING |
| MINIMUM INSIDE BENDING RADIUS | 11.000 INCHES |
| TEMP RATING | -65.0 FAHRENHEIT AND 450.0 FAHRENHEIT SINGLE RESPONSE |