| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END CONNECTION DESIGN | STRAIGHT SECOND END |
| END FLANGE CONSTRUCTION | SOLID SECOND END |
| BURST TEST PRESSURE | 2000.0 POUNDS PER SQUARE INCH |
| CONNECTION TYPE | PLAIN FACE FLANGE FIRST END |
| CONNECTION TYPE | PLAIN FACE FLANGE SECOND END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| EXTERIOR COLOR | NATURAL |
| FEATURES PROVIDED | INTERNAL SUPPORT |
| FLANGE STYLE | RECTANGULAR (INCLUDES SQUARE) FIRST END |
| HYDROSTATIC TEST PRESSURE | 1300.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 1.120 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED CORROSION RESISTANT STEEL WIRE, PARTIAL COVERAGE AND OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| OUTSIDE DIAMETER | 1.440 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 23.125 INCHES NOMINAL WORKING |
| MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON AND WATER SINGLE RESPONSE |
| MINIMUM INSIDE BENDING RADIUS | 8.000 INCHES |
| OPERATING PRESSURE | 800.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |