| BURST TEST PRESSURE | 5000.0 POUNDS PER SQUARE INCH |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| HYDROSTATIC TEST PRESSURE | 2500.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.539 INCHES MINIMUM AND 0.593 INCHES MAXIMUM |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED CORROSION RESISTANT STEEL WIRE, PARTIAL COVERAGE AND OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| OUTER COVERING ENVIRONMENTAL PROTECTION | ABRASION RESISTANT AND CORROSION RESISTANT |
| OUTSIDE DIAMETER | 0.774 INCHES MINIMUM AND 0.820 INCHES MAXIMUM |
| MEASURING METHOD AND LENGTH | 15.500 INCHES NOMINAL WORKING |
| MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| MINIMUM INSIDE BENDING RADIUS | 4.000 INCHES |
| OPERATING PRESSURE | 1000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| VACUUM IN TORR | 76.2 |