| END CONNECTION DESIGN | ELBOW FIRST END |
| END FLANGE CONSTRUCTION | SPLIT FIRST END |
| END FITTING COMPONENT AND MATERIAL | COMPLETE FITTING STEEL ALL ENDS |
| ANGLE BETWEEN RIGID ELBOW FITTINGS IN DEG | 90.0 |
| BURST TEST PRESSURE | 16000.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | PLAIN SWIVEL W/ GASKET GROOVE FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLOW ANGLE | 90.0 DEGREES FIRST END |
| HYDROSTATIC TEST PRESSURE | 8000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.380 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 2ND LAYER SPIRALLY LAID CORROSION RESISTANT STEEL WIRE |
| LAYER COMPOSITION AND LOCATION | 3RD LAYER SPIRALLY LAID CORROSION RESISTANT STEEL WIRE |
| LAYER COMPOSITION AND LOCATION | 4TH LAYER SPIRALLY LAID CORROSION RESISTANT STEEL WIRE |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER SPIRALLY LAID CORROSION RESISTANT STEEL WIRE |
| LAYER COMPOSITION AND LOCATION | OUTER LAYER RUBBER IMPREGNATED BRAIDED FABRIC |
| OUTER COVERING ENVIRONMENTAL PROTECTION | OIL RESISTANT |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | HOSE ASSY |
| MEASURING METHOD AND LENGTH | 39.380 INCHES MINIMUM OVERALL AND 40.380 INCHES MAXIMUM OVERALL |
| MEDIA FOR WHICH DESIGNED | HYDRAULIC FLUID SINGLE RESPONSE |
| OPERATING PRESSURE | 4000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| SPECIAL FEATURES | EXTERNAL PROTECTION TYPE AND LOCATION- OVERALL SPRING GUARD, ROUND CORROSION RESISTING STEEL COIL , INNER CONVEYING TUBE MATERIAL-RUBBER, SYNTHETIC |
| TEMP RATING | -40.0 FAHRENHEIT AND 250.0 FAHRENHEIT SINGLE RESPONSE |