| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| AC VOLTAGE RATING | 10.0 VOLTS NOMINAL FIRST OPERATING POWER RQMT |
| OUTPUT FREQUENCY RATING | 200.0 MEGAHERTZ NOMINAL |
| OUTPUT IMPEDANCE RATING | 50.0 OHMS |
| OUTPUT FREQUENCY BANDWIDTH | 500.0 MEGAHERTZ NOMINAL |
| MULTIPLEXING METHOD | FREQUENCY DIVISION |
| SPECIAL FEATURES | 1-SLOT C-SIZE,REGISTER BASED VXI MODULE;TWENTY 3 TO 1 MULTIPLEXER CONFIGURATIONS;3 TO 1,6 TO 1,9 TO 1,UP TO 60 TO 1 BY CASCADING 20 MULTIPLEXERS;500MHZ BANDWIDTH;SIMULTANEOUS MULTIPLE CASCADE COMBINATIONS;ISOLATION 50DB AT 200MHZ;PROGRAMMABLE WITH SCPI COMMANDS OR REGISTER READ/WRITES; JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME: 60 CHANNEL 50OHMS RF CASCADE MULTIPLEXER |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | RF CASCADE MULTIPLEXER |
| SPECIAL TEST FEATURES | PRODUCT DISCONTINUED;CURRENTLY SUPPORTED UNTIL 1SEPTEMBER 2012 |
| SUPPLEMENTARY FEATURES | EACH MODULE IS SHIPPED WITH AGILENT KIT E1470-80003 CONTAINING 10 CABLE HOUSING ASSEMBLIES (1250-2563) AND 80 CABLE JACKS |