6625-00-080-2919 AMMETER Index 5950-00-080-2925 TRANSFORMER,POWER

National Stock Number:
5905-00-080-2920

Federal Supply Class:
5905

National Item Identification Number:
000802920

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
237852-137695RAYTHEON COMPANY
RL3006-500-97S175263KEYSTONE CARBON CO INC


Techincal Specification:
ZERO POWER RESISTANCE864.000 OHMS
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
INCLOSURE TYPEENCAPSULATED
RELIABILITY INDICATORNOT ESTABLISHED
STYLE DESIGNATORDISK
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
MAXIMUM POWER DISSIPATION RATING1.00 WATTS
MAXIMUM OPERATING TEMP150.0 DEG CELSIUS
THERMAL TIME CONSTANT IN SECONDS44.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS9.0
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-4.47
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
-21.5 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
37.8 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
50.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
104.4 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
150.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP95.8 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
9.8 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
2.9 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
500.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT
308.5 OHMS 5TH RESISTANCE-TEMPERATURE POINT
51.5 OHMS 6TH RESISTANCE-TEMPERATURE POINT
16.2 OHMS 7TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.0 TO 20.0 1ST RESISTANCE-TEMPERATURE POINT
-10.0 TO 10.0 2ND RESISTANCE-TEMPERATURE POINT
-10.0 TO 10.0 3RD RESISTANCE-TEMPERATURE POINT
-10.0 TO 10.0 4TH RESISTANCE-TEMPERATURE POINT
-10.0 TO 10.0 5TH RESISTANCE-TEMPERATURE POINT
-10.0 TO 10.0 6TH RESISTANCE-TEMPERATURE POINT
-20.0 TO 20.0 7TH RESISTANCE-TEMPERATURE POINT
BODY OUTSIDE DIAMETER0.345 INCHES NOMINAL
BODY WIDTH0.160 INCHES NOMINAL
TERMINAL LENGTH1.827 INCHES NOMINAL
TERMINAL DIAMETER0.010 INCHES NOMINAL