| AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| BODY LENGTH | 0.285 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 0.150 INCHES MAXIMUM |
| INCLOSURE TYPE | ENCAPSULATED |
| MAXIMUM OPERATING TEMP | 150.0 CELSIUS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 6.6 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0 TO 5.0 ALL RESISTANCE-TEMPERATURE POINTS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.99 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 112.0 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.83 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| ZERO POWER RESISTANCE | 112.000 KILOHMS |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -5.11 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 211.0 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.29 MEGOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | ROD |
| SURFACE TREATMENT | COPPER AND TIN TERMINAL |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -21.5 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 104.4 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 25.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 37.8 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| TERMINAL LENGTH | 2.000 INCHES NOMINAL |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 45.0 |