5905-01-084-5890 RESISTOR,FIXED,WIRE WOUND,INDUCT Index 5905-01-084-5892 RESISTOR,FIXED,WIRE WOUND,INDUCT

National Stock Number:
5905-01-084-5891

Federal Supply Class:
5905

National Item Identification Number:
010845891

Description:
RESISTOR,FIXED,WIRE WOUND,INDUCT

Detail:
INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.


Manufacturer Information:
1720M45P0166464GENERAL ELECTRIC CO
956146-1B82577RAYTHEON COMPANY
MIL-PRF-39007/881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39007/881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILR3900781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RS1A13991637VISHAY DALE ELECTRONICS, LLC
TS1-2W3R33F02985TEPRO OF FLORIDA INC
RW70U3R32F81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RWR80S3R32FM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RWR80S3R32FP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RWR80S3R32FR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RWR80S3R32FS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL RESISTANCE3.320 OHMS
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER275.0
BODY DIAMETER0.094 INCHES NOMINAL
BODY LENGTH0.406 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
NUCLEAR HARDNESS CRITICAL FEATUREHARDENED
POWER DISSIPATION RATING IN WATTS2.000 FREE AIR
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
RELIABILITY INDICATORESTABLISHED
RESISTANCE TOLERANCE IN PERCENT-1.000 TO 1.000
SPECIAL FEATURESNUCLEAR HARDNESS CRITICAL ITEMS
SPECIFICATION/STANDARD DATA81349-MIL-R-39007/8 GOVERNMENT SPECIFICATION
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 275.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-50.0 TO 50.0
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MIL-R-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).