ZERO POWER RESISTANCE | 15.000 KILOHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
INCLOSURE TYPE | ENCAPSULATED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | ROD |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
MAXIMUM POWER DISSIPATION RATING | 125.00 MILLIWATTS |
AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
THERMAL TIME CONSTANT IN SECONDS | 60.0 |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.2 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 10.7 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| 18.1 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| 21.4 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| 25.0 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| 28.5 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 1ST RESISTANCE-TEMPERATURE POINT |
| -9.0 TO 9.0 2ND RESISTANCE-TEMPERATURE POINT |
| -7.0 TO 7.0 3RD RESISTANCE-TEMPERATURE POINT |
| -9.0 TO 9.0 4TH RESISTANCE-TEMPERATURE POINT |
| -12.0 TO 12.0 5TH RESISTANCE-TEMPERATURE POINT |
| -15.0 TO 15.0 6TH RESISTANCE-TEMPERATURE POINT |
BODY LENGTH | 0.390 INCHES MINIMUM AND |
| 0.420 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 0.125 INCHES MINIMUM AND |
| 0.155 INCHES MAXIMUM |
TERMINAL LENGTH | 1.000 INCHES MINIMUM |
TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
REFERENCE TEMP IN DEG CELSIUS | 25.0 |