ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION |
ACTUATOR TYPE | SINGLE SHAFT |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 60.0 ALL SECTIONS |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 ALL SECTIONS |
BEARING TYPE | BALL SHAFT |
BODY DIAMETER | 1.062 INCHES NOMINAL |
BODY LENGTH | 1.900 INCHES MAXIMUM |
BODY STYLE | CYLINDRICAL SERVO MOUNTED |
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 352.0 NOMINAL |
ELECTRICAL RESISTANCE PER SECTION | 10.0 KILOHMS 1ST SECTION AND 20.0 KILOHMS 2ND SECTION |
FEATURES PROVIDED | SWITCH |
FIXED TAP QUANTITY PER SECTION | 1 1ST SECTION AND 3 2ND SECTION |
FUNCTION CHARACTERISTIC PER SECTION | 1ST SECTION 180 DEG SINE AND 2ND SECTION LINEAR |
FUNCTION CONFORMITY PER SECTION | 1ST SECTION ABSOLUTE CONFORMITY AND 2ND SECTION INDEPENDENT LINEARITY |
FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.50 TO 1.50 1ST SECTION AND -0.50 TO 0.50 2ND SECTION |
LATERAL RUNOUT | 0.002 INCHES |
PILOT DIAMETER | 0.9688 INCHES NOMINAL |
PILOT LENGTH | 0.0620 INCHES NOMINAL |
PILOT DIAMETER RUNOUT | 0.0015 INCHES |
MAXIMUM RUNNING TORQUE | 0.30 INCH-OUNCES |
MAXIMUM STARTING TORQUE | 0.30 INCH-OUNCES |
MOUNTING LIP DEPTH | 0.0620 INCHES NOMINAL |
MOUNTING LIP DIAMETER | 1.0620 INCHES NOMINAL |
MOUNTING METHOD | CLAMP RING |
POWER DISSIPATION RATING PER SECTION IN WATTS | 0.75 FREE AIR 1ST SECTION AND 2.0 FREE AIR 2ND SECTION |
RELIABILITY INDICATOR | NOT ESTABLISHED |
RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 ALL SECTIONS |
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
SECTION QUANTITY | 2 |
SHAFT LENGTH | 0.625 INCHES NOMINAL |
SHAFT DIAMETER | 0.125 INCHES NOMINAL |
SHAFT END PLAY | 0.003 INCHES |
SHAFT RADIAL PLAY | 0.002 INCHES |
SHAFT RUNOUT | 0.001 INCHES |
SHAFT STYLE | ROUND, SLOTTED |
SWITCH OPERATING POSITION | START OF ROTATION |
SWITCH TYPE | ROTARY |
SWITCH VOLTAGE RATING IN VOLTS | 12.0 |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY OPEN, BOTH POSITIONS MAINTAINED |
SWITCH CURRENT TYPE AND RATING IN AMPS | 0.0012 DC |
TAP LOCATION TOLERANCE PER SECTION | -1.0 TO 1.0 DEG ANGULAR ROTATION ALL SECTIONS |
TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 90.0 1ST SECTION AND 10.0 2ND SECTION AND 35.0 2ND SECTION AND 60.0 2ND SECTION |
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -300.0 TO 300.0 1ST SECTION |
TERMINAL LOCATION | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
TERMINAL TYPE AND QUANTITY | 12 TURRET |
UNDERCUT DIAMETER | 0.975 INCHES MAXIMUM |
UNDERCUT WIDTH | 0.0620 INCHES NOMINAL |