5990-01-292-2369 RESOLVER,ELECTRICAL Index 5935-01-292-2371 BACKSHELL,ELECTRICAL CONNECTOR

National Stock Number:
5905-01-292-2370

Federal Supply Class:
5905

National Item Identification Number:
012922370

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
238283-437695RAYTHEON COMPANY
STD015415454RTIE HOLDINGS LLC


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY OUTSIDE DIAMETER0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM
BODY WIDTH0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM
CUBIC MEASURE0.0005 CUBIC INCHES
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING500.00 MILLIWATTS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS4.0
REFERENCE TEMP IN DEG CELSIUS25.0
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 SEVENTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 SIXTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.0 TO 5.0 FIRST RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.0 TO 5.0 FOURTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.0 TO 5.0 SECOND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.0 TO 5.0 THIRD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-7.0 TO 7.0 FIFTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.0 MEGOHMS FIRST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.477 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP675.0 OHMS SIXTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP73.42 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-5.0 TO 5.0
ZERO POWER RESISTANCE10.000 KILOHMS
ZERO POWER RESISTANCE AT SPECIFIED TEMP3.595 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP32.74 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP338.0 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORSPHERICAL
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER125.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER75.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-15.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.018 INCHES NOMINAL
TERMINAL LENGTH1.000 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
TEST DATA DOCUMENT37695-238283 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
THERMAL TIME CONSTANT IN SECONDS8.0