5970-01-087-3196 INSULATOR,BUSHING Index 5910-01-087-3198 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-01-087-3197

Federal Supply Class:
5910

National Item Identification Number:
010873197

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CSR13E225MR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003-01-276481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-39003/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER0.135 INCHES NOMINAL
BODY LENGTH0.286 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION2.200 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
DC LEAKAGE AT REFERENCE TEMP0.400 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT4.0000
ELECTRICAL POLARIZATIONPOLARIZED
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION20.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.0100
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL DIAMETER0.020 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-39003/1 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION