| ELECTRICAL POLARIZATION | POLARIZED |
| BODY DIAMETER | 0.910 INCHES MAXIMUM |
| BODY LENGTH | 3.125 INCHES MINIMUM AND 3.343 INCHES MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
| CAPACITIVE ELECTRODE MATERIAL | ALUMINUM |
| CAPACITANCE VALUE PER SECTION | 5200.000 MICROFARADS SINGLE SECTION |
| CASE INSULATION MATERIAL | PLASTIC |
| DC LEAKAGE AT REFERENCE TEMP | 144.000 MICROAMPERES |
| EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS | 0.056 |
| NONDERATED OPERATING TEMP | -55.0 CELSIUS MINIMUM AND 105.0 CELSIUS MAXIMUM |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 16.0 DC SINGLE SECTION |
| REFERENCE TEMP AT WHICH RATED | 25.0 CELSIUS |
| RELIABILITY INDICATOR | ESTABLISHED |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.000 |
| SPECIAL FEATURES | TWO TERMINALS AT EACH END |
| TOLERANCE RANGE PER SECTION | -10.00 TO 75.00 PERCENT SINGLE SECTION |
| SPECIFICATION/STANDARD DATA | 81349-MIL-C-39018/7 GOVERNMENT SPECIFICATION |
| TERMINAL TYPE AND QUANTITY | 4 UNINSULATED WIRE LEAD |
| TEST DATA DOCUMENT | 81349-MIL-C-39018 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |