5950-00-085-0201 REACTOR Index 5915-00-085-0204 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-00-085-0202

Federal Supply Class:
5915

National Item Identification Number:
000850202

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
337-458-900170210HONEYWELL INTERNATIONAL INC.
61F1014412406ELPAC ELECTRONICS INC
GF756107294GENISCO FILTER CORP
GF756113050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON


Techincal Specification:
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.3 1ST RADIO INTERFERENCE 1ST FUNCTION
0.3 2ND RADIO INTERFERENCE 2ND FUNCTION
INCLOSURE TYPEENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT 1ST FUNCTION
2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION26.0 VOLTS AC 1ST RADIO INTERFERENCE AND
28.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
26.0 VOLTS AC 2ND RADIO INTERFERENCE AND
28.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION150.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
150.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL LENGTH1.750 INCHES MAXIMUM
OVERALL HEIGHT0.780 INCHES MAXIMUM
OVERALL WIDTH1.380 INCHES MAXIMUM
BODY LENGTH1.180 INCHES MAXIMUM
BODY WIDTH1.060 INCHES MAXIMUM
UNTHREADED MOUNTING HOLE DIAMETER0.150 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.452 INCHES MAXIMUM
TEST DATA DOCUMENT70210-337-458-9001 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM TEMP RISE25.0 DEG CELSIUS
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE200.0 VOLTS AT SEA LEVEL
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 55.0
OPERATING TEMP RANGE-65.0 TO 85.0 DEG CELSIUS
BODY SURFACE TREATMENTTIN