5950-00-086-8760 COIL,RADIO FREQUENCY Index 5960-00-086-8764 ELECTRON TUBE

National Stock Number:
5915-00-086-8762

Federal Supply Class:
5915

National Item Identification Number:
000868762

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
526-9413-0013499ROCKWELL COLLINS, INC.
526-9413-00013499ROCKWELL COLLINS, INC.
552-9425-00213499ROCKWELL COLLINS, INC.
552-9425-00295105ROCKWELL COLLINS, INC.
526-9413-00095105ROCKWELL COLLINS, INC.


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION498.33 KILOHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK
INCLOSURE TYPEHERMETICALLY SEALED
FREQUENCY BAND WIDTH PER FUNCTION496.95 KILOHERTZ BLANK AND
499.70 KILOHERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT 1ST FUNCTION
2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
1 TAB, SOLDER LUG GROUND 3RD FUNCTION
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION270.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION20.0 KILOHMS BLANK
INPUT IMPEDANCE PER FUNCTION W/LOAD270.0 OHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT20.0 KILOHMS BLANK
OVERALL LENGTH2.438 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.412 INCHES MINIMUM AND
0.454 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY5 TERMINAL
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION496.00 KILOHERTZ BLANK AND
496.95 KILOHERTZ BLANK AND
499.70 KILOHERTZ BLANK AND
500.00 KILOHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND
1.5 MAXIMUM BLANK 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-RESISTANCE BLANK
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE100.0 VOLTS AT ALTITUDE
VIBRATION RESISTANCE RANGE IN HERTZ200.0 TO 500.0
OPERATING TEMP RANGE0.0 TO 60.0 DEG CELSIUS
THE MANUFACTURERS DATA
MANUFACTURERS CODE95105
DESIGN CONTROL REFERENCE526-9413-000


Click here to Register for Free 30-day Trial