5961-00-249-1638 TRANSISTOR Index 5915-00-249-1640 FILTER,BAND PASS

National Stock Number:
5915-00-249-1639

Federal Supply Class:
5915

National Item Identification Number:
002491639

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
20-0312-0011402HISONIC, LLC
67A32A33030003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
BODY HEIGHT3.540 INCHES MAXIMUM
BODY LENGTH2.040 INCHES MAXIMUM
BODY WIDTH2.040 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.358 KILOHERTZ BLANK AND 2.443 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT3.910 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
REFERENCE FREQUENCY PER FUNCTION2.4 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.272 KILOHERTZ BLANK AND 2.358 KILOHERTZ BLANK AND 2.443 KILOHERTZ BLANK AND 2.528 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE