5961-00-400-5973 TRANSISTOR Index 5915-00-400-5978 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-00-400-5977

Federal Supply Class:
5915

National Item Identification Number:
004005977

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
27-3-99-0024012406ELPAC ELECTRONICS INC
337-454-900270210HONEYWELL INTERNATIONAL INC.
GF-850407294GENISCO FILTER CORP
GF-850413050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON


Techincal Specification:
BODY HEIGHT1.100 INCHES MAXIMUM
BODY LENGTH1.180 INCHES MAXIMUM
BODY SURFACE TREATMENTTIN
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.452 INCHES MAXIMUM
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
OVERALL HEIGHT1.390 INCHES MAXIMUM
OVERALL LENGTH1.750 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE200.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION150.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION150.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION150.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION150.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.4 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.4 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING TEMP RANGE-65.0 TO 85.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
SPECIAL FEATURESTERMINALS ON ONE SURFACE; 1.060 IN. MAX W
UNTHREADED MOUNTING HOLE DIAMETER0.150 INCHES MAXIMUM
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
TEST DATA DOCUMENT70210-337-454-9002 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)