| BODY HEIGHT | 1.250 INCHES MAXIMUM |
| BODY LENGTH | 3.062 INCHES NOMINAL |
| BODY MATERIAL | METAL |
| BODY SURFACE TREATMENT | TIN |
| BODY WIDTH | 2.875 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.500 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.500 INCHES NOMINAL |
| FEATURES PROVIDED | MOISTURE RESISTANT AND SHOCK RESISTANT |
| FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0 |
| FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 7.0 AND 60.0 |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OVERALL LENGTH | 3.374 INCHES NOMINAL |
| MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 250.0 VOLTS AT SEA LEVEL |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| NOMINAL THREAD SIZE | 0.138 INCHES |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING TEMP RANGE | -55.0 TO 100.0 CELSIUS |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| SPECIAL FEATURES | FOUR FILTERED FUNCTIONS |
| VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 500.0 |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| UNPACKAGED UNIT WEIGHT | 12.000 OUNCES NOMINAL |