5915-00-675-0089 FILTER,LOW PASS Index 5915-00-675-0091 FILTER,BAND PASS

National Stock Number:
5915-00-675-0090

Federal Supply Class:
5915

National Item Identification Number:
006750090

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
432614-196214RAYTHEON COMPANY
G27901864959AMERICAN TELEPHONE AND TELEGRAPH CO
GS5687964959AMERICAN TELEPHONE AND TELEGRAPH CO


Techincal Specification:
BODY HEIGHT3.640 INCHES MAXIMUM
BODY LENGTH1.770 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.770 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS32.0 MINIMUM BLANK AND 5.0 MINIMUM BLANK AND 52.0 MINIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION190.00 KILOHERTZ BLANK AND 194.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD5.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT100.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT4.130 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.164 INCHES
OPERATING TEMP RANGE-35.0 TO 75.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION192.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION182.00 KILOHERTZ BLANK AND 190.00 KILOHERTZ BLANK AND 194.00 KILOHERTZ BLANK AND 202.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE