4140-00-790-3721 FAN,CIRCULATING Index 5340-00-790-3724 BRACKET,MOUNTING

National Stock Number:
5915-00-790-3722

Federal Supply Class:
5915

National Item Identification Number:
007903722

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
B218355828527L3HARRIS TECHNOLOGIES, INC.
B2183558ISSUEB28528ITT INDUSTRIES INC ITT AEROSPACE COMMUNICATIONS DIV EAST


Techincal Specification:
BODY HEIGHT3.250 INCHES NOMINAL
BODY LENGTH2.250 INCHES NOMINAL
BODY WIDTH1.219 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 NOMINAL BLANK AND 3.0 NOMINAL BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.969 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.625 INCHES NOMINAL
FREQUENCY BAND WIDTH PER FUNCTION2.41 KILOHERTZ BLANK AND 2.58 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.190 INCHES
OVERALL HEIGHT3.531 INCHES NOMINAL
REFERENCE FREQUENCY PER FUNCTION2.5 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.29 KILOHERTZ BLANK AND 2.41 KILOHERTZ BLANK AND 2.58 KILOHERTZ BLANK AND 2.71 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE