3010-00-880-0687 GEARCASE-MOTOR Index 3895-00-880-0690 MIXER,CONCRETE,TRAILER MOUNTED

National Stock Number:
5915-00-880-0689

Federal Supply Class:
5915

National Item Identification Number:
008800689

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
1065354718876U S ARMY AVIATION AND MISSILE COMMAND
713880-10605869RAYTHEON COMPANY
GF4200-1707294GENISCO FILTER CORP
GF4200-17LIMITEABFD4SEBBFJ07294GENISCO FILTER CORP
GF4200-17LIMITEABFD4SEBBFJ13050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
GF4200-1713050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON


Techincal Specification:
BODY LENGTH3.500 INCHES NOMINAL
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER1.750 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH5.920 INCHES MAXIMUM
MAXIMUM TEMP RISE25.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION1.5 VOLTS AC BLANK AND 1.5 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNEF
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.750 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS15.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES