5915-01-028-6633 FILTER,BAND PASS Index 5915-01-028-6636 FILTER,BAND PASS

National Stock Number:
5915-01-028-6634

Federal Supply Class:
5915

National Item Identification Number:
010286634

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
2887837-110001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
2887837-13B150RAYTHEON COMPANY
8BE812/105-EE23042TRILITHIC, INC.
X8BE812/105-3-50-EE23042TRILITHIC, INC.
2887837-149956RAYTHEON COMPANY
2887837-154X10RAYTHEON COMPANY


Techincal Specification:
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER1.250 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK AND 70.0 MINIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION759.50 MEGAHERTZ BLANK AND 864.50 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH9.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY1 CLAMP LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 75.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION812.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESSPRUANCE CLASS DD (963); MISSILE SYSTEMS,NATO SEA SPARROW; MISSILE SYSTEMS,SURFACE
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.35 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION654.50 MEGAHERTZ BLANK AND 759.50 MEGAHERTZ BLANK AND 864.50 MEGAHERTZ BLANK AND 969.50 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES