3110-01-042-2423 BEARING,BALL,PIVOT Index 5930-01-042-2425 SWITCH,ROTARY

National Stock Number:
5915-01-042-2424

Federal Supply Class:
5915

National Item Identification Number:
010422424

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
GF-5080-50C-BR07294GENISCO FILTER CORP
GF-5080-50C-BR13050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON


Techincal Specification:
OPERATING CURRENT RATING PER FUNCTION IN AMPS50.0 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 4TH RADIO INTERFERENCE 4TH FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD INPUT 1ST FUNCTION
4 THREADED STUD OUTPUT 2ND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 1ST RADIO INTERFERENCE AND
400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
125.0 VOLTS AC 2ND RADIO INTERFERENCE AND
400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
125.0 VOLTS AC 3RD RADIO INTERFERENCE AND
400.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
125.0 VOLTS AC 4TH RADIO INTERFERENCE AND
400.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
400.0 4TH RADIO INTERFERENCE 4TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.25 VOLTS AC 1ST RADIO INTERFERENCE AND
4.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
1.25 VOLTS AC 2ND RADIO INTERFERENCE AND
4.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
1.25 VOLTS AC 3RD RADIO INTERFERENCE AND
4.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
1.25 VOLTS AC 4TH RADIO INTERFERENCE AND
4.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
OVERALL LENGTH9.900 INCHES NOMINAL
BODY LENGTH6.900 INCHES NOMINAL
BODY HEIGHT3.500 INCHES NOMINAL
BODY WIDTH4.700 INCHES NOMINAL
UNTHREADED MOUNTING HOLE DIAMETER0.205 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH7.430 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH3.500 INCHES NOMINAL
MAXIMUM TEMP RISE25.0 DEG CELSIUS
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE250.0 VOLTS AT SEA LEVEL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE800.0 VOLTS AT SEA LEVEL
OPERATING TEMP RANGE-55.0 TO 85.0 DEG CELSIUS
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN