5915-01-128-3215 FILTER,BAND PASS Index 5905-01-128-3217 RESISTOR,THERMAL

National Stock Number:
5915-01-128-3216

Federal Supply Class:
5915

National Item Identification Number:
011283216

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
325135-237695RAYTHEON COMPANY
CPN 692-266223OBERON USA INC
CPN692-258997VECTRON INTERNATIONAL, INC.


Techincal Specification:
BODY HEIGHT0.402 INCHES MAXIMUM
BODY LENGTH0.500 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.500 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.200 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION3.11 MEGAHERTZ BLANK AND 7.11 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS6.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION125.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT0.702 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE-30.0 TO 85.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION500.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION5.1 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION4.56 KILOHERTZ BLANK AND 3.11 MEGAHERTZ BLANK AND 7.11 MEGAHERTZ BLANK AND 30.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial