5915-01-192-8561 FILTER,BAND PASS Index 5915-01-192-8563 FILTER,LOW PASS

National Stock Number:
5915-01-192-8562

Federal Supply Class:
5915

National Item Identification Number:
011928562

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
726-032-00117903ANDREW SCICOMM INC
SC50-10000/X100-0/050140K&L MICROWAVE LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION1.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY LENGTH3.290 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.750 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS80.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.670 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION9.90 GIGAHERTZ BLANK AND 10.10 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-JACK
INPUT TERMINAL MANUFACTURER CODE17903
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONSMA-JACK
OUTPUT TERMINAL MANUFACTURER CODE17903
OVERALL HEIGHT0.800 INCHES NOMINAL
OVERALL LENGTH4.050 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION10.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
UNTHREADED MOUNTING HOLE DIAMETER0.160 INCHES NOMINAL
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION9.9 GIGAHERTZ BLANK AND 10.1 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION9.70 GIGAHERTZ BLANK AND 9.90 GIGAHERTZ BLANK AND 10.10 GIGAHERTZ BLANK AND 10.30 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES