5935-01-193-5217 CONNECTOR,PLUG,ELECTRICAL Index 5905-01-193-5219 RESISTOR

National Stock Number:
5915-01-193-5218

Federal Supply Class:
5915

National Item Identification Number:
011935218

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
332650959364HONEYWELL INTERNATIONAL INC.
332650977068ALLIED-SIGNAL INC DBA ALLIED-SIGNAL AEROSPACE CO ELECTRODYNAMICS DIV
7924-113222A. T. PARKER, INC.
F2136996733SFE TECHNOLOGIES


Techincal Specification:
BODY HEIGHT1.650 INCHES MAXIMUM
BODY LENGTH2.570 INCHES MINIMUM AND 2.630 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.320 INCHES MINIMUM AND 2.380 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.865 INCHES MINIMUM AND 1.885 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.115 INCHES MINIMUM AND 2.135 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY8 SOLDER STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
OVERALL HEIGHT2.410 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 6TH RADIO INTERFERENCE SIXTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE FIFTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE SIXTH FUNCTION
SPECIAL FEATURESEIGHT FILTERED FUNCTIONS
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial