5935-01-196-9423 CONNECTORBODY,RECEPTACLE,ELECTR Index 5915-01-196-9425 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-196-9424

Federal Supply Class:
5915

National Item Identification Number:
011969424

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
307A8716-189954BAE SYSTEMS CONTROLS INC.
RF1066813619EMS DEVELOPMENT CORPORATION


Techincal Specification:
AVERAGE LIFE RATING IN HOURS1000.0
BODY HEIGHT2.000 INCHES MAXIMUM
BODY LENGTH2.500 INCHES MAXIMUM
BODY WIDTH2.250 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.940 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.690 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY5 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONMS27471Y-1135PB
INPUT TERMINAL MANUFACTURER CODE96906
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE AND 28.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE AND 28.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE AND 28.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE AND 28.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 5TH RADIO INTERFERENCE AND 28.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE56.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE FIFTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES