5915-01-293-4008 FILTER,BAND PASS Index 5915-01-293-4010 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-293-4009

Federal Supply Class:
5915

National Item Identification Number:
012934009

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
425321-100752L3HARRIS TECHNOLOGIES, INC.
6C80-13980/4680-050140K&L MICROWAVE LLC


Techincal Specification:
BODY HEIGHT0.610 INCHES MINIMUM AND 0.650 INCHES MAXIMUM
BODY LENGTH1.830 INCHES MINIMUM AND 1.870 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.360 INCHES MINIMUM AND 0.400 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.530 INCHES MINIMUM AND 1.570 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION11.64 GIGAHERTZ BLANK AND 16.32 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE50140
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE50140
OVERALL HEIGHT1.170 INCHES MINIMUM AND 1.290 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.086 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION13.98 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ2.000
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION11.64 GIGAHERTZ BLANK AND 16.32 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.6 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION7.00 GIGAHERTZ BLANK AND 11.64 GIGAHERTZ BLANK AND 16.32 GIGAHERTZ BLANK AND 20.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES