| BODY LENGTH | 2.594 INCHES MINIMUM AND 2.656 INCHES MAXIMUM |
| BODY STYLE | AXIAL TERMINAL TYPE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.469 INCHES MINIMUM AND 3.531 INCHES MAXIMUM |
| CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS | 15.0 300 PCT OF CURRENT RATING |
| CIRCUIT OVER-CURRENT INTERRUPTION TYPE | TIME DELAY |
| CONTINUOUS CURRENT RATING IN AMPS | 120.000 |
| FEATURES PROVIDED | NONRENEWABLE FUSIBLE ELEMENT |
| INTERRUPTION INDICATOR METHOD | OPAQUE BODY |
| OVERALL DIAMETER | 1.031 INCHES MINIMUM AND 1.093 INCHES MAXIMUM |
| OVERALL LENGTH | 4.125 INCHES NOMINAL |
| MATERIAL | FIBER CASE |
| MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 AC AND 125.0 DC |
| MOUNTING SLOT WIDTH | 0.235 INCHES MINIMUM AND 0.297 INCHES MAXIMUM |
| SPECIFICATION/STANDARD DATA | 81349-MIL-F-15160/3D GOVERNMENT SPECIFICATION |
| SURFACE TREATMENT | NICKEL TERMINAL |
| TEST DATA DOCUMENT | 81349-MIL-F-15160 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |