4730-00-260-4292 TEE,PIPE Index 5910-00-260-4311 CAPACITOR,VARIABLE,AIR DIELECTRI

National Stock Number:
5925-00-260-4298

Federal Supply Class:
5925

National Item Identification Number:
002604298

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
1730-281108241LOCKHEED MARTIN CORP LOCKHEED MARTIN MISSION SYSTEMS
78-166-174193EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
AP12-1406-181541SENSATA TECHNOLOGIES MARYLAND, INC


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESETTRIP-RESET
ACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWOBETWEEN POLE ONE AND TWO
BODY LENGTH1.562 INCHES MAXIMUM1.562 INCHES MAXIMUM
BODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPEMULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH1.281 INCHES MAXIMUM1.281 INCHES MAXIMUM
BUSHING LENGTH0.390 INCHES MINIMUM AND 0.390 INCHES MINIMUM AND 0.565 INCHES MAXIMUM0.565 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.875 INCHES NOMINAL0.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.625 INCHES NOMINAL0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ60.0 ALL LOCATIONS60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALEDHERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONSSERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE18.0 AMPERES AC FIRST LOCATION18.0 AMPERES AC FIRST LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE250.0 MILLIAMPERES AC SECOND LOCATION250.0 MILLIAMPERES AC SECOND LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS300.0 AC ALL LOCATIONS300.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE1.828 INCHES MAXIMUM1.828 INCHES MAXIMUM
NOMINAL THREAD SIZE0.375 INCHES0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC ALL LOCATIONS240.0 AC ALL LOCATIONS
POLE QUANTITY22
RESET METHODMANUALMANUAL
TERMINAL TYPE AND QUANTITY4 WIRE HOOK4 WIRE HOOK
THREAD QUANTITY PER INCH3232
THREAD SERIES DESIGNATORUNEFUNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.055 MINIMUM AT 200 PCT AND 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.240 MAXIMUM AT 400 PCT ALL LOCATIONS0.240 MAXIMUM AT 400 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTICINSTANTANEOUS AND INSTANTANEOUS AND TIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS
TRIP RELEASE METHODMAGNETIC ALL LOCATIONSMAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0 ALL LOCATIONS115.0 ALL LOCATIONS