5925-01-030-2970 CIRCUIT BREAKER Index 5925-01-030-2973 CIRCUIT BREAKER

National Stock Number:
5925-01-030-2972

Federal Supply Class:
5925

National Item Identification Number:
010302972

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
CD1-A3-15-120-374193EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESETTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONEAT POLE ONE
ARC QUENCHING METHODAIRAIR
BODY LENGTH5.790 INCHES MINIMUM AND 5.790 INCHES MINIMUM AND 5.810 INCHES MAXIMUM5.810 INCHES MAXIMUM
BODY STYLESINGLE POLE TYPESINGLE POLE TYPE
BODY WIDTH1.016 INCHES MINIMUM AND 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM1.036 INCHES MAXIMUM
BOSS HEIGHT0.209 INCHES MINIMUM AND 0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM0.229 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.537 INCHES MINIMUM AND 3.537 INCHES MINIMUM AND 3.557 INCHES MAXIMUM3.557 INCHES MAXIMUM
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATIONOVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.740 INCHES MINIMUM AND 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM2.760 INCHES MAXIMUM
FRAGILITY FACTORMODERATELY RUGGEDMODERATELY RUGGED
FREQUENCY IN HERTZ60.0 SINGLE LOCATION60.0 SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANTMOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATIONSERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREETRIP FREE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 AC SINGLE LOCATION120.0 AC SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE1 TOGGLE
MATERIALPLASTIC CASEPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE15.0 AMPERES AC SINGLE LOCATION15.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC SINGLE LOCATION5000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) AND 2 THREADED HOLE(S) AND 1 UNTHREADED HOLE(S) AND 1 UNTHREADED HOLE(S) AND 1 SLOT1 SLOT
MOUNTING SLOT WIDTH0.178 INCHES NOMINAL0.178 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE2.599 INCHES MINIMUM AND 2.599 INCHES MINIMUM AND 2.619 INCHES MAXIMUM2.619 INCHES MAXIMUM
NOMINAL THREAD SIZE0.138 INCHES0.138 INCHES
POLE QUANTITY11
RESET METHODMANUALMANUAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.300 MINIMUM AT 200 PCT AND 0.300 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT SINGLE LOCATION1.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATIONTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODMAGNETIC-HYDRAULIC SINGLE LOCATIONMAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION125.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER0.164 INCHES NOMINAL0.164 INCHES NOMINAL
STORAGE TYPEGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY2 THREADED STUD2 THREADED STUD
THREAD QUANTITY PER INCH3232
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)UNIFIED NATIONAL COARSE (UNC)