| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| OVERALL LENGTH | 2.890 INCHES NOMINAL |
| OVERALL WIDTH | 1.900 INCHES NOMINAL |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | DC HI-AMP THERMAL CIRCUIT BREAKER |
| MATERIAL | PLASTIC CASE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES DC SINGLE LOCATION |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3000.0 DC SINGLE LOCATION |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE(S) |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 30.0 DC SINGLE LOCATION |
| OVERALL HEIGHT | 1.090 INCHES NOMINAL |
| RESET METHOD | MANUAL |
| SPECIAL FEATURES | CASE MATERIAL IS PHENOLIC; MAXIMUM VOLTAGE IS 42 VOLTS DC; IGNITION PROTECTED (CONFORMING TO SAE J1171); WATERPROOF; SWITCH TYPE IS PUSH BUTTON; 1/4" TERMINAL STUDS; PANEL MOUNT |
| TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL |