| BULB DIAMETER | 0.320 INCHES NOMINAL |
| BULB LENGTH | 1.500 INCHES NOMINAL |
| CAPILLARY TUBE LENGTH | 96.0 INCHES NOMINAL |
| CONTACT ADJUSTMENT RANGE | +100.00 TO 250.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT POINTER |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 4.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 235.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 99.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
| OVERALL DIAMETER | 3.125 INCHES NOMINAL |
| OVERALL HEIGHT | 1.812 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING FACILITY PATTERN | THREE POSITION CIRCULAR |
| MOUNTING METHOD | BASE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| STYLE DESIGNATOR | CYLINDRICAL |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| TERMINAL TYPE | WIRE LEAD |