| BULB DIAMETER | 0.188 INCHES NOMINAL |
| BULB LENGTH | 15.000 INCHES NOMINAL |
| CAPILLARY TUBE LENGTH | 24.000 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTMENT RANGE | +300.00 TO 575.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 35.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
| OVERALL HEIGHT | 2.750 INCHES NOMINAL |
| OVERALL LENGTH | 3.906 INCHES NOMINAL |
| OVERALL WIDTH | 3.062 INCHES NOMINAL |
| MOUNTING METHOD | BASE |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| OPERATING TEMP RATING | 625.0 FAHRENHEIT MAXIMUM |
| SPECIAL FEATURES | TWO 6-32 THD MTG HOLES 1.750 IN. C TO C |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| TERMINAL TYPE | SCREW |