| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 7.0 AMPERES RESISTIVE LOAD AND 4.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
| CONTACT STIMULUS RATING | 240.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 100.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| MEDIA FOR WHICH DESIGNED | GAS |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING TEMP RATING | -85.0 FAHRENHEIT MINIMUM AND 275.0 FAHRENHEIT MAXIMUM |
| PRESSURE SWITCH TYPE | GAGE |
| PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
| SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |
| STYLE DESIGNATOR | CYLINDRICAL W/MOUNTING LUGS |