| CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
| CONTACT LOAD CURRENT RATING | 30.0 AMPERES RESISTIVE LOAD AND 25.0 AMPERES INDUCTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL |
| CONTACT LOAD CURRENT RATING | 30.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
| CONTACT VOLTAGE RATING IN VOLTS | 120.0 LOWEST DC VOLTAGE RATING AT SEA LEVEL |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
| CONTACT VOLTAGE RATING IN VOLTS | 500.0 AC AT SEA LEVEL |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.812 INCHES NOMINAL SECOND MOUNTING FACILITY |
| FEATURES PROVIDED | ACTUATOR KNOB AND DUMMY SECTION |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT |
| OVERALL HEIGHT | 3.657 INCHES MINIMUM AND 3.719 INCHES MAXIMUM |
| OVERALL LENGTH | 10.183 INCHES NOMINAL |
| OVERALL WIDTH | 4.375 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | FOUR POSITION CIRCULAR FIRST MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE SECOND MOUNTING FACILITY |
| MOUNTING FACILITY CIRCLE RADIUS | 1.609 INCHES NOMINAL FIRST MOUNTING FACILITY |
| MOUNTING METHOD | BRACKET(S) AND THREADED HOLE(S) FIRST MOUNTING FACILITY |
| MOUNTING METHOD | BRACKET(S) AND UNTHREADED HOLE(S) SECOND MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.250 INCHES FIRST MOUNTING FACILITY |
| SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DESC PRODUCTION STANDARD NO. L03998; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.312 INCHES NOMINAL SECOND MOUNTING FACILITY |
| STYLE DESIGNATOR | TAP, CIRCUIT SELECTOR |
| SWITCH ACTUATOR INDEXING POSITION QUANTITY | 2 SINGLE ACTUATOR |
| SWITCH ACTUATOR POSITIONING INCREMENT | 90.0 DEGREES SINGLE ACTUATOR |
| SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
| SWITCH CONTACT BASIC DESIGN | NONPILE-UP NONSYMMETRICAL |
| TERMINAL TYPE | TAB W/SCREW |
| THREAD CLASS | 2B FIRST MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 20 FIRST MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) FIRST MOUNTING FACILITY |