| BODY DIAMETER | 0.720 INCHES MAXIMUM |
| BODY HEIGHT | 0.360 INCHES MAXIMUM |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
| CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD AND 1.5 AMPERES INDUCTIVE LOAD AND 0.5 AMPERES LAMP LOAD FIRST VOLTAGE |
| CONTACT STIMULUS RATING | 41.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 49.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 2.00 DIFFERENTIAL POINT MINIMUM DEGREES FAHRENHEIT AND 5.00 DIFFERENTIAL POINT MAXIMUM DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.930 INCHES MINIMUM AND 0.944 INCHES MAXIMUM |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
| OVERALL LENGTH | 1.465 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| MOUNTING SLOT WIDTH | 0.094 INCHES MINIMUM AND 0.114 INCHES MAXIMUM |
| MOUNTING METHOD | BRACKET(S) AND SLOT |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| OPERATING TEMP RATING | -10.0 FAHRENHEIT MINIMUM AND 250.0 FAHRENHEIT MAXIMUM |
| OVERALL HEIGHT | 0.360 INCHES MAXIMUM |
| SPECIFICATION/STANDARD DATA | 81349-MIL-S-24236/20 GOVERNMENT SPECIFICATION |
| STYLE DESIGNATOR | DISC W/FLANGE |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | TAB, SOLDER LUG |
| TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |