5305-01-089-2537 SCREW,SHOULDER Index 5940-01-089-2540 TERMINAL,STUD

National Stock Number:
5940-01-089-2539

Federal Supply Class:
5940

National Item Identification Number:
010892539

Description:
TERMINAL,STUD

Detail:
A terminal, generally postlike, having an axial portion of its body designed for projecting through or into a panel, or the like, for mounting. Requires the use of tool(s) for attachment of wire. The conductor connection may be insulated from the mounting. Excludes TERMINAL, FEEDTHRU. See also TERMINAL, QUICK DISCONNECT and TERMINAL SET, QUICK DISCONNECT.


Manufacturer Information:
2184230377SMITHS AEROSPACE INC. ELECTRONIC SYSTEMS-GRAND RAPIDS
21842-130377SMITHS AEROSPACE INC. ELECTRONIC SYSTEMS-GRAND RAPIDS
5210-4-117117ELECTRONIC MOLDING CORP
5210-4-161638ADVANCED INTERCONNECTIONS CORPORATION


Techincal Specification:
BASIC SHAPE STYLETUBULAR, ROUND
TERMINAL LENGTH0.185 INCHES
OVERALL HEIGHT0.295 INCHES
OVERALL DIAMETER0.196 INCHES
CONDUCTOR ACCOMMODATION TYPEBIFURCATED U-FORK SINGLE END
SLOT WIDTH0.060 INCHES SINGLE END
LARGEST WIDTH0.125 INCHES SINGLE END
MOUNTING METHOD STYLEPRESS FIT KNURL
MINOR BUSHING DIAMETER0.185 INCHES
MAJOR BUSHING DIAMETER0.196 INCHES
MINOR BUSHING LENGTH0.045 INCHES
ELECTRICAL INSULATION FEATUREINSULATING MOUNTING BUSHING
IDENTIFICATION CODE COLORBROWN
MATERIALPLASTIC DIALLYL PHTHALATE INSULATION
COPPER ALLOY OVERALL EXCEPT INSULATION
MATERIAL DOCUMENT AND CLASSIFICATIONMIL-M-14,SDG-F MIL SPEC SINGLE MATERIAL RESPONSE INSULATION
QQ-B-626 FED SPEC SINGLE MATERIAL RESPONSE OVERALL
SURFACE TREATMENTSILVER CONDUCTOR ACCOMMODATION FIRST LAYER
GOLD CONDUCTOR ACCOMMODATION SECOND LAYER
CHROMATE MOUNTING FACILITY FIRST LAYER
CADMIUM MOUNTING FACILITY SECOND LAYER
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONQQ-S-365,TYPE II FED SPEC 1ST TREATMENT RESPONSE CONDUCTOR ACCOMMODATION FIRST LAYER
MIL-G-45204 MIL SPEC 2ND TREATMENT RESPONSE CONDUCTOR ACCOMMODATION SECOND LAYER
QQ-P-416,TYPE II,CLASS 3 FED SPEC 1ST TREATMENT RESPONSE MOUNTING FACILITY FIRST LAYER
QQ-P-416,TYPE II,CLASS 3 FED SPEC 1ST TREATMENT RESPONSE MOUNTING FACILITY SECOND LAYER
PRECIOUS MATERIALGOLD AND
SILVER
PRECIOUS MATERIAL AND LOCATIONTERMINAL PLATING GOLD AND
TERMINAL PLATING SILVER