| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.400 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.300 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 2 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FEATURES PROVIDED | POLARIZED AND LATCHING CONTACTS |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 30.0 DC |
| OVERALL HEIGHT | 0.602 INCHES MAXIMUM |
| OVERALL LENGTH | 1.640 INCHES MAXIMUM |
| OVERALL WIDTH | 1.480 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.122 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 500.0 OHMS NOMINAL ALL WINDINGS |
| WINDING QUANTITY | 2 |
| TERMINAL TYPE AND QUANTITY | 16 PIN ALL FUNCTIONS |
| TIME DELAY | 0.003 SECONDS NOMINAL FIXED RELEASE TIME |
| TIME DELAY | 0.010 SECONDS NOMINAL FIXED OPERATE TIME |