| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 64.000 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 600.0 AMPERES DC MOTOR LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 600.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| OVERALL HEIGHT | 4.000 INCHES MAXIMUM |
| OVERALL LENGTH | 4.000 INCHES MAXIMUM |
| OVERALL WIDTH | 4.000 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.206 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 8 THREADED STUD ALL FUNCTIONS |