| DUTY TYPE | CONTINUOUS |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES DC INDUCTIVE LOAD |
| OVERALL HEIGHT | 3.090 INCHES NOMINAL |
| OVERALL LENGTH | 2.180 INCHES NOMINAL |
| OVERALL WIDTH | 1.810 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 ELECTRICAL PLUG CONNECTOR SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 350.0 MILLIAMPERES DC SINGLE WINDING |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| SPECIFICATION/STANDARD DATA | 88044-AN3308-2 GOVERNMENT STANDARD |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG ALL FUNCTIONS |
| TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |