| DUTY TYPE | CONTINUOUS |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 26.0 DC |
| OVERALL HEIGHT | 0.735 INCHES MAXIMUM |
| OVERALL LENGTH | 1.397 INCHES MAXIMUM |
| OVERALL WIDTH | 1.375 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 13.5 MILLIAMPERES DC SINGLE WINDING |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 36.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| WINDING DC RESISTANCE RATING | 1.0 KILOHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 20 PIN ALL FUNCTIONS |