| DESIGN CONTROL REFERENCE | IC5181C101C6AAW/TRANSITION-BASE |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 02989 |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 440.0 AC |
| AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 440.0 AC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 27.0 AMPERES AC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 345.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 440.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 100.0 MILLIAMPERES AC SINGLE WINDING |
| FREQUENCY IN HERTZ | 60.0 NOMINAL |
| TERMINAL TYPE AND QUANTITY | 17 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| OVERALL LENGTH | 5.370 INCHES NOMINAL |
| OVERALL WIDTH | 6.430 INCHES NOMINAL |
| OVERALL HEIGHT | 3.930 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.938 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.250 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2B SINGLE MOUNTING FACILITY |