| DUTY TYPE | CONTINUOUS |
| AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC RESISTIVE LOAD |
| AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 29.0 DC |
| AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES DC INDUCTIVE LOAD |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.313 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 40.141 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 29.0 DC |
| OVERALL HEIGHT | 2.750 INCHES MINIMUM AND 2.810 INCHES MAXIMUM |
| OVERALL LENGTH | 4.970 INCHES MINIMUM AND 5.030 INCHES MAXIMUM |
| OVERALL WIDTH | 2.780 INCHES MINIMUM AND 2.840 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 29.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES MINIMUM AND 0.206 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 12 THREADED STUD ALL FUNCTIONS |